genlp
genloop
Genloop · Inventory · Gas turbines

Used Gas Turbines for Sale

Heavy-frame, aeroderivative and trailer-mounted gas turbines that Genloop holds as principal, from 20 MW mobile units to a 388 MW combined cycle plant. Each one is restored, re-warrantied and delivered as a single scope, for grid, industrial and data center load that cannot wait in a new-build queue.

01 · In the register

Five gas turbine holdings.

Suited to utilities and IPPs replacing retired capacity, developers who need firm power years before a new frame can be delivered, and industrial sites and data centers building their own generation. Every unit is held or controlled by Genloop; specifications, records and pricing are shared directly under NDA.

All unitsGas turbinesSteam turbinesEngine plantsGenerators & transformersCapital partsData center power50 HzMobile units
NºUnitRatingHistoryStatus
01GE 9FA combined cycle plant388 MW · 50 Hz2006 · 36,000 hrsAvailable 02GE 9E gas turbine130 MW · 50 Hz2001 · 60,000 hrsAvailable 03Siemens V94.2 combined cycle block200 MW · 50 Hz1992 · 127,400 hrsAvailable 04GE TM2500 mobile gas turbines, 4 units80 MW · 50/60 HzZero-hour overhaulContract pending 05GE LM2500 gas turbines, pair2 × 20 MW · 60 Hz2000Available
Selling a unit? Start here · Indicative register · Specifications and availability shared directly · [email protected]
02 · Questions

What buyers ask first.

01

What is the difference between a heavy-frame and an aeroderivative gas turbine?

Heavy-frame machines such as the GE 9E, 9FA and Siemens V94.2 are built for continuous duty at 100 MW and above, with exhaust temperatures that suit combined cycle operation. Aeroderivatives such as the LM2500 and the trailer-mounted TM2500 descend from aircraft engines: lighter, smaller, and able to start and reach full load in minutes, which is why they lead for peaking, mobile and fast-track service.

02

Can a used gas turbine built for 50 Hz run on a 60 Hz grid?

Grid frequency is set by the generator and the shaft speed that drives it. Single-shaft heavy frames are designed for one frequency, and moving between the two is a major engineering exercise that is rarely economic. Some aeroderivative packages, including the TM2500, are offered for both. The frequency on each unit page is the one the machine suits as it stands.

03

What condition is a used gas turbine in when it leaves Genloop?

Every unit is inspected by Genloop’s own engineers before it enters the register, and leaves after a fixed-scope refurbishment at a principal shop, re-warrantied to OEM standard. Hours, starts and outage history are shared directly under NDA, together with the records a buyer’s engineers will want to see.

03 · The Difference

Every unit arrives de-risked.

Nothing here is a spec sheet with a contact button. Equipment leaves Genloop restored, warrantied, and delivered, with one firm accountable end to end.

Restored & re-warrantied

Fixed-scope refurbishment at the industry's principal shops, warrantied to OEM standard.

Title verified

Condition and title verified on site, directly with owners, before a unit enters this register.

Logistics managed

Dismantling, export compliance, and transport handled as one scope, insured throughout.

Installed & commissioned

Field engineering and EPC coordination through first fire, with O&M planning and spares.

Every asset here began as someone's idle investment. Recovery is where it came from; redeployment is where it goes.

Reading, before you buy or sell
The Midterms Just Made Deliverable Megawatts the Hottest Asset in AmericaFor developers · 14 min Who Is Buying Used Power in America, and Why They Are Paying New Prices for ItFor developers · 20 min

Specifications, records and pricing are shared directly.

Direct
Contact→
For owners
Sell Equipment→