Unused Alstom 160 MW Steam Turbine Generator for Sale, 60 Hz

2006 · never fired · 1900 psia at 1050°F, reheat

On site5 images

An unused Alstom 160 MW reheat steam turbine generator set, built in 2006 and never fired, complete with its 187.65 MVA, 18 kV TEWAC generator, static excitation, control valves, gland sealing skid, sound enclosure, auxiliaries and tooling. Steam inlet 1900 psia at 1050°F, reheat to 1050°F, maximum throttle flow 835,000 lb/h. 60 Hz service.

Scope of supply
  • Turbine assembly
  • Steam control valves and operators
  • Gland sealing skid
  • One generator package, 18.0 kV, 187.65 MVA, TEWAC
  • One static excitation system
  • Power system stabiliser
  • Key phasor
  • Sound enclosure with lighting and HVAC
  • Steam turbine and generator accessory equipment: controls, HVAC, lighting, fire protection, electrical package, oil systems
  • Electrical package including MCCs
  • Steam turbine tools and maintenance equipment
  • Field erection supervision, man-weeks to be confirmed with the OEM
  • Piping from the valves to the steam turbine inlets, including some prefabricated piping

Steam inlet conditions 1900 psia nominal at 1050°F, reheated to 1050°F, with a maximum throttle flow of 835,000 lb/h. Serial number 60 WY21Z-085.

OEMAlstom (GE)
Model160 MW reheat steam turbine generator set, serial 60 WY21Z-085
Equipment typeSteam turbine generator
Quantity1
Rating160 MW
Frequency60 Hz
Year2006
Operating hours0, never fired
ConfigurationReheat condensing. Inlet 1900 psia at 1050°F, reheat to 1050°F, maximum throttle flow 835,000 lb/h
Scope of supplyComplete set with generator, excitation, valves, enclosure, auxiliaries and tooling; the full list is on the page
ConditionUnused, never fired
StatusAvailable
Generator187.65 MVA · 18 kV · TEWAC
Enquire about this unit→

Specifications, records and pricing are shared directly.

Combined cycle pairings

Sized for a block behind
any of five gas turbine sets.

Net plant figures from a heat-balance model of this steam turbine behind each set, with duct firing and an air-cooled condenser at 59°F, 60% relative humidity and sea level. The steam turbine carries 159 to 160 MW in every case. Each configuration uses typical mid-range performance for its class, except the SGT-800, which reflects the latest model.

Gas turbinesNet powerNet heat rate, BTU/kWh LHVNet efficiency, LHV
1 × GE 7F.04333.0 MW6,57351.9%
3 × Siemens SGT-800329.4 MW6,56652.0%
2 × GE 7E.03322.2 MW6,78850.3%
4 × GE 6B.03317.5 MW6,85649.8%
2 × GE 6FA300.0 MW6,93149.2%

Other combinations are possible; the model is rerun for a specific site and machine. Open a diagram for the full heat balance.

Also in the register
Full inventory register→
08Škoda 60 MW steam turbine generator60 MW · 50 Hz1998 · 58,205 hrsAvailable 01GE 9FA combined cycle plant388 MW · 50 Hz2006 · 36,000 hrsAvailable 03Siemens V94.2 combined cycle block200 MW · 50 Hz1992 · 127,400 hrsAvailable
Reading, before you buy or sell
Who Is Buying Used Power in America, and Why They Are Paying New Prices for ItFor developers · 20 min The Midterms Just Made Deliverable Megawatts the Hottest Asset in AmericaFor developers · 14 min